Err

← Luxeri Optics LabTOOL No. 02 · OPTICAL FIBERS

Numerical aperture and acceptance angle of an optical fiber

Calculate the numerical aperture and acceptance cone from core, cladding and external refractive indices. Adjust a ray to explore guidance in the fiber.

Refractive indices: 0.001–10, with n꜀ > nɢ. Input angle: 0–89.9°. Use indices at the same wavelength and temperature.

1 · Acceptance cone at the input
Cross-section of the acceptance coneThe acceptance half-angle is measured from the fiber axis.External medium · n₀ = 1.000CoreAxisαHalf-angle: 30.00°
2 · Ray path in the core and cladding
Guidance of a meridional ray in the fiberGuidance depends on incidence at the core–cladding interface.CladdingCoreCladding

Internal angles are measured from the axis and the normal to the wall.

Cone / guided rayInput ray / thresholdUnguided ray

2D section of a 3D cone. Dimensions are illustrative; line lengths and thicknesses do not represent optical power.

Numerical aperture · NA

0.500

Half-angle · θmax

30.00°

Full angle · 2θmax

60.00°

Core–cladding critical angle

70.39°
Guided ray

Total internal reflection at the wall provides guidance in this geometrical model.

NUMERICAL APERTURE, DIMENSIONLESS

NA = √(n꜀² − nɢ²)

√(1.490² − 1.4036²) = 0.500

ACCEPTANCE HALF-ANGLE

θmax = arcsin(NA / n₀)

arcsin(0.500 / 1.000) ≈ 30.00°

How to use this calculator

NA = √(n꜀² − nɢ²), and θmax = arcsin(NA/n₀), capped at 90°. The full acceptance cone angle is 2θmax.

The core index must exceed the cladding index. At the wall, ic = arcsin(nɢ/n꜀) and incidence is i = 90° − β. Total internal reflection requires i > ic. At equality, guidance is at its threshold. A higher external index narrows the acceptance cone.

Assumptions and limitations

Straight step-index fiber with uniform, isotropic, transparent, non-absorbing core and cladding. The input face is normal to the axis, and meridional rays enter at its center. Skew rays, modes, coupling efficiency, bending losses, Fresnel intensities, polarization and propagation losses are excluded. Use indices at the same wavelength and temperature.

Frequently asked questions

Does every ray inside the cone transmit all its power?

No. The cone is a geometrical guidance condition. Input reflection and other losses can reduce transmitted power. At the exact threshold, robust guidance is not guaranteed.

Can I change the values directly?

Yes. Enter values directly or use the available controls. Results use unrounded calculations. Displayed values and diagrams are rounded or illustrative.

Explore all the free Luxeri Optics Lab tools or read our optical guide.